Magnetic pump in the course of daily use recommended that the majority of users should do the following maintenance work:
(1) Check the magnetic pump pipeline and the combination of loose phenomenon. Rotate the magnetic pump by hand to see if the magnetic pump is spirited.
(2) If there is abnormal sound of magnetic pump should stop immediately check the reasons.
(3) Unscrew the diversion screw plug of the magnetic pump body, and pour water (or slurry).
(4) close the outlet valve and outlet pressure gauges and import vacuum gauge.
(5) Move the motor to see if the motor is steered correctly.
(6) magnetic pump in operation, the bearing temperature can not exceed the ambient temperature 35C, the maximum temperature shall not exceed 80C.
(7) try to control the flow and head of the magnetic pump in the range indicated on the plate to ensure that the maximum efficiency of the magnetic pump operation, in order to get the maximum energy-saving effect.
(8) start the motor, when the normal operation of the magnetic pump, open the outlet pressure gauge and inlet vacuum pump as it shows the appropriate pressure, and gradually open the gate valve, while checking the motor load conditions.
(9) Add bearing lubricating oil to the bearing body, observe the oil level should be at the center line of the oil standard, lubricating oil should be replaced or replenished promptly.
(10) to stop using the magnetic pump, first close the gate valve, pressure gauge, and then stop the motor.
(11) magnetic pump in the first month of work, after 100 hours to replace the oil, after every 500 hours, oil change time.
(12) Often adjust the packing gland to ensure normal drip leakage in the packing room.
(13) Regular inspection of the sleeve wear, wear and tear should be promptly replaced.
(14) When the magnetic pump is used in the winter season, after stopping the pump, unscrew the drain plug at the lower part of the pump to release the medium. Prevent cracking.
(15) long-term deactivation of the magnetic pump, pump all the necessary open, dry the water, the rotating parts and joints coated with grease installed.
October 15, 2024
September 18, 2024
April 20, 2024
October 12, 2023
이 업체에게 이메일로 보내기
October 15, 2024
September 18, 2024
April 20, 2024
October 12, 2023
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.